
The NSX Data Plane
The NSX Data Plane performs stateless packet forwarding and enforces security policies using ephemeral tables the Control Plane disseminates.
Additionally, the Data Plane reports network topology changes to the Control Plane and sends traffic statistics to the Management Plane.
Member servers – either physical hosts or virtual appliances – run NSX kernel modules and agents. Those servers that join the NSX logical fabric and participate in the data plane traffic are called Transport Nodes.
In this Part 4, we shift our focus from the Management and Control Planes to the NSX Data Plane. You will learn how Transport Nodes serve as the foundational elements for distributed forwarding and security enforcement.
In the Exploring NSX Building Blocks module, we cover the following main topics:
- Part 1:
- Part 2:
- Part 3:
- Part 4:
- Part 5:
- Part 6:
By the end of Part 4, you will understand the deployment prerequisites, configuration steps, and validation procedures required to integrate Transport Nodes into the NSX fabric. This ensures the environment is ready for dynamic network virtualization and scalable East-West traffic processing.
NSX Transport Nodes overview
NSX Transport Nodes are the fundamental components of the NSX Data Plane. These nodes are where virtualized network functions occur. They form the distributed data plane that powers NSX’s advanced networking and security capabilities.
Host Transport Nodes
Host Transport Nodes are responsible for running user workloads like VMs, virtual appliances, containers, and bare-metal applications. In particular, these nodes can be classified into the following types:
- ESXi Transport Nodes: Also referred to as Hypervisor Transport Nodes, these nodes are part of a vSphere deployment. They run the NSX kernel modules and agents natively, as ESXi add-on components.
- Bare-Metal Transport Nodes: These are standalone physical servers running supported Linux or Windows operating systems. They are ideal for hosting workloads that reside outside of hypervisor environments or require specialized network services.
NOTE
NSX-T Data Center 3.x supported KVM-based Hypervisor Transport Nodes. However, support for KVM hypervisors was deprecated in NSX 4.0 and is no longer available in current releases.
Edge Transport Nodes
Edge Transport Nodes provide centralized services, such as North-South routing, DHCP, NAT, and VPN. They can be deployed as virtual appliances or on bare-metal servers.
Each Edge Transport Node contributes compute resources to host one or more NSX service instances. With this in mind, to ensure high availability and service resilience, Edge Nodes must be added to an Edge Cluster. An Edge Cluster can consist of one to ten Edge Nodes, and is a mandatory construct for consuming centralized NSX services.
Prerequisites for Transport Nodes deployment
The prerequisites for deploying Transport Nodes in the NSX Data Plane vary depending on the Transport Node type. NSX relies on each node’s virtual switching capabilities to create logical segments and enable overlay networking.
Virtual switching requirements
- ESXi Hypervisor Transport Nodes: The NSX switching model on ESXi has evolved through different NSX versions.
- NSX-T Data Center (pre-3.0) used the NSX-managed Virtual Distributed Switch (N-VDS), deployed alongside the native vSphere VDS. Basically, the N-VDS was a fork of the vSphere VDS, modified to support NSX-specific functionalities.
- Starting with NSX-T Data Center 3.0 and vSphere 7.0, VMware integrated NSX support directly into the vSphere VDS. Consequently, this integration eliminated the need to maintain a separate switch type for NSX. While the N-VDS remained available for backward compatibility, it was deprecated in favor of the unified vSphere VDS. As a result, the vSphere 7 VDS became the recommended host switch to use for all new NSX deployments.
- As of NSX 4.0, support for the N-VDS on ESXi has been completely removed. Hence, the vSphere VDS is now the only supported virtual switch on ESXi for NSX integration.
- Edge and Bare-Metal Transport Nodes
- These nodes use Open vSwitch (OVS), an open-source virtual switch that supports OpenFlow – managed by the Open Networking Foundation (ONF) – and OVSDB – authored by Nicira – for dynamic configuration.
- NSX abstracts each individual OVS instance through an N-VDS, enabling a consistent and distributed switch configuration across multiple transport nodes.
OS and package dependencies
- ESXi Hypervisor Transport Nodes: NSX kernel modules and agents are installed on supported vSphere ESXi hosts running standard installation images. One or more preconfigured vSphere VDS version 7.0 or newer are required to successfully deploy and configure NSX components.
- Edge Transport Nodes: All necessary components – including OVS and NSX kernel module and agents – are pre-packaged within the deployment image. As such, no additional software setup is required beyond deploying the image.
- Bare-Metal Transport Nodes: These nodes require a supported Linux distribution and installation of OS-specific third-party packages to enable NSX kernel modules and OVS capabilities. Due to version-specific dependencies, refer to the official NSX documentation for detailed prerequisites per Linux distribution.
MTU considerations for overlay traffic
In addition to the prerequisites above, proper Maximum Transmission Unit (MTU) sizing is crucial for overlay traffic.
In essence, since GENEVE encapsulation adds overhead to packet headers, jumbo frames must be enabled. While the minimum MTU is 1,600 bytes, VMware strongly recommends configuring an MTU of 1,700 bytes or higher to ensure end-to-end packet delivery and optimal performance.
Consequently, ensure consistent MTU settings are applied across:
- vSphere Virtual Distributed Switches
- Host physical NIC uplinks
- Physical switches and routers carrying overlay traffic
NSX Transport Zones
To begin with, all Transport Nodes in the NSX Data Plane – regardless of type – must be associated with one or more Transport Zones. Transport Zones define the scope of NSX logical segments and determine which segments are realized on which Transport Nodes. Consequently, whenever a logical segment is created, it must be associated with exactly one Transport Zone.
Furthermore, a single Transport Zone can span multiple vSphere clusters, offering deployment flexibility across diverse infrastructure layouts.
There are two types of Transport Zones:
- Overlay Transport Zones: Enable the creation of Overlay Logical Segments, each identified by a unique Virtual Network Identifier (VNI). These segments use the GENEVE protocol to encapsulate and transport workload traffic across L2/L3 physical networks. As a result, workloads connected to the same logical segment can communicate at Layer 2 – even if located on different Transport Nodes – without requiring physical network reconfiguration.
- VLAN Transport Zones: Enable the creation of VLAN Logical Segments, each mapped to a unique 802.1Q VLAN ID. Consequently, these segments are typically used for integration with external physical infrastructure or to support North-South traffic.
By default, NSX provides two preconfigured Transport Zones:
- nsx-overlay-transportzone
- nsx-vlan-transportzone
However, administrators can create additional Transport Zones as needed. To do so, navigate to:
System > Configuration > Fabric > Transport Zones, then click ADD TRANSPORT ZONE.

When creating a Transport Zone, the following inputs are required:
- A unique Name and optional Description.
- The desired Traffic Type: either Overlay (default) or VLAN.
IMPORTANT
When creating a new Transport Zone, it is essential to select the correct traffic type – either Overlay or VLAN – before saving. Once the zone is created, its traffic type cannot be changed. Therefore, if the incorrect type is selected, the Transport Zone must be deleted and recreated.
Moreover, an important but often overlooked detail is that any logical segments associated with the zone must first be deleted – along with their configurations – before the Transport Zone itself can be removed.
Therefore, always double-check your selection before saving to avoid unnecessary rework and configuration rollback.
Deployment workflows overview
To participate in the NSX Data Plane, Transport Nodes require the installation of a discrete set of NSX kernel modules and agents. This set of components is referred to as the NSX LCP Bundle. The deployment method of these bundles depends on the specific node type. The following summarizes the available approaches:
- ESXi Hypervisor Transport Nodes: Install the NSX LCP Bundle through the standard vSphere mechanism using vSphere Installation Bundles (VIB). VIBs serve as the functional equivalent of Linux DEB and RPM packages. Alternative deployment methods include:
- Automated deployment through the NSX Manager UI (preferred).
- Automated deployment using vSphere Lifecycle Manager.
- Manual deployment using ESXCLI, followed by NSXCLI, and finalized in NSX Manager.
- Edge Transport Nodes: Whether deployed as virtual appliances or on bare-metal, they share the same software codebase. All NSX LCP Bundle components are pre-packaged in the deployment image, eliminating the need for separate installation steps.
- Edge Transport Node virtual appliances can leverage:
- Automated deployment through the NSX Manager UI (preferred).
- Manual deployment using the vSphere Client, OVF Tool, or PowerCLI, followed by NSXCLI and configuration in NSX Manager.
- Edge Transport Node bare-metal hosts require:
- Manual deployment using the NSX Edge ISO image, followed by NSXCLI and configuration in NSX Manager.
- Edge Transport Node virtual appliances can leverage:
- Bare-Metal Transport Nodes: They depend on the native package management system of their respective operating systems. DEB packages for Ubuntu. RPM packages for Red Hat Enterprise Linux (RHEL), CentOS, Oracle Linux, and SUSE Linux Enterprise Server (SLES). MSI packages for Windows. Bare-Metal Transport Nodes can be deployed through:
- Automated deployment through the NSX Manager UI (preferred).
- Manual deployment via the operating system’s package manager, followed by NSXCLI and configuration in NSX Manager.
Common NSX Transport Nodes parameters
Regardless of the Transport Node type and deployment method, each Transport Node in the NSX Data Plane must be configured with several key NSX networking parameters:
- The Host Switch used to instantiate logical segments. One or more Host Switches may be configured.
- For ESXi Hypervisor Transport Nodes, the vCenter Server and a vSphere VDS version 7.0 or later.
- For Edge and Bare-Metal Transport Nodes, the N-VDS name that will abstract the underlying Open vSwitch instance.
- A Host Switch can be associated with exactly one Overlay Transport Zone and one or more VLAN Transport Zones.
- An Uplink Profile to control number and type of uplinks – pNICs or Bonds – to use, Teaming and Failover Policy, VLAN ID, and MTU size. Several default profiles are available for quick use. Alternatively, custom profiles can be created for environment-specific deployment needs.
- If connecting to an Overlay Transport Zone, Tunnel End Point (TEP) settings must be selected:
- IP address type: IPv4 or IPv6.
- IP address assignment: DHCP, IP Pool, or AutoConf (IPv6 only).
- Optionally, under Advanced Configuration > Mode, the most appropriate networking stack:
- Standard (default): Supported by all Transport Node types.
- Enhanced Datapath – Standard: Supported by ESXi only (see note).
- Enhanced Datapath – Performance: Supported by ESXi only (see note).
- Finally, the Teaming Policy Uplink Mapping enables binding host switch uplinks to pNICs or Edge virtual switch portgroups.
NOTE
Enhanced Datapath (EDP) is designed for workloads requiring extremely high packet rates and ultra-low latency network performance. It delivers superior throughput and reduced latency compared to the standard data path available on all Transport Node types.
EDP achieves this by leveraging DPU-powered SmartNICs or EDP-capable standard NICs and the Data Plane Development Kit (DPDK). DPDK is a Linux Foundation project offering optimized libraries for fast packet processing in user space.
EDP mode is supported only on compatible hardware. Therefore, always consult the VMware Compatibility Guide to verify support before enabling Enhanced Datapath.
Advantages of using the NSX Manager UI
By navigating to System > Configuration > Fabric > Hosts, administrators gain access to four tabs dedicated to Transport Nodes deployment. Specifically, each tab – Clusters, Other Nodes, Standalone and Transport Node Profile – offers a dedicated wizard for guided deployment steps. These wizards are designed to collect connection details and configuration inputs, simplifying the Transport Nodes provisioning process.

Moreover, using the NSX Manager UI helps catching configuration issues early in the workflow, reducing manual troubleshooting effort. When errors occur, the UI often provides a RESOLVE button to automatically address and fix deployment issues. Therefore, the NSX Manager UI significantly improves accuracy, reduces errors, and streamlines Transport Nodes deployment.
NOTE
Sometimes, the RESOLVE task may require reinstating the node credentials, including user, password, and thumbprint.
In short, a host certificate thumbprint acts as a unique identifier, similar to a human thumbprint. It is a hash of the certificate’s public key and serves as a reference. The thumbprint is required for REST API calls invoked by some RESOLVE workflows.
Therefore, it is essential to understand how to retrieve the thumbprint. By leveraging the following steps, you can retrieve the host certificate thumbprint necessary for the RESOLVE workflow to run successfully:
- For ESXi hosts, access the ESXi shell and run:
openssl x509 -in /etc/vmware/ssl/rui.crt -fingerprint -sha256 -noout
- For Linux hosts:
- First locate the host’s public key, usually found at:
/etc/ssh/ssh_host_rsa_key.pub - Then, generate the SHA256 hash of the key with the following command:
awk '{print $2}' <path_to_host_public_key> | base64 -d | sha256sum -b | sed 's/ .*$//' | xxd -r -p | base64
- First locate the host’s public key, usually found at:
ESXi Hypervisor Transport Nodes
Automated deployment through the NSX Manager UI
In a vSphere environment with a vCenter Server paired with NSX, ESXi hosts are prepared in the following ways:
- For vSphere Clusters: All ESXi hosts within the cluster are prepared together in a single round. Clicking the CONFIGURE NSX button from the Clusters tab triggers the NSX Installation wizard.
- For Standalone ESXi Hosts: These hosts are prepared individually. Clicking the ADD HOST NODE from the Standalone tab triggers the Add Host Node wizard.
In particular, for vSphere Clusters, we can utilize a Transport Node Profile. This profile stores all required Host Switch parameters for orchestrating the configuration of each ESXi host in the cluster. The Transport Node Profile can then be applied to a vSphere Cluster from the NSX Installation wizard. This approach accelerates the configuration process and ensures uniform configuration across all nodes in the cluster.

The parameters that can be observed in the Host Switch wizard are the ones described earlier in this post.
Automated deployment using vSphere Lifecycle Manager
Alternatively, NSX installation can be automated using vSphere Lifecycle Manager to manage all vSphere Cluster hosts with a single image.
- First, create a vSphere Cluster with the Manage all hosts in the cluster with a single image option enabled (default). Next, chose how to set up the cluster’s image:
- Compose a new image.
- Import image from an existing host in the vCenter inventory.
- Import image from a new host.

- As a result, the cm-inventory service in the NSX Management Cluster pulls the new vSphere Cluster object. The cluster is listed under System > Configuration > Fabric > Hosts > Clusters.
- Clicking CONFIGURE NSX attaches a Transport Node Profile to the vSphere Cluster.
- Consequently, vSphere Lifecycle Manager pulls the NSX LCP Bundle from
/repository/<version>/HostComponents/<esxi_version>on NSX Manager nodes. The NSX LCP Bundle is added to the vCenter Server image repository as a Solution Component for that cluster. - From this point on, adding hosts to the vSphere Cluster triggers an automatic NSX installation and configuration. vSphere Lifecycle Manager installs the NSX VIBs, registers the host, and configures the NSX switch.
Manual deployment using ESXCLI, followed by NSXCLI, and finalized in NSX Manager
Lastly, ESXi Hypervisor Transport Nodes may also be manually prepared from the ESXi shell.
The required NSX LCP Bundle, containing all necessary VIBs, must be installed using the ESXCLI. In order to do that, the bundle can be downloaded from VMware’s website. Alternatively, it can be retrieved from the NSX Management Cluster nodes local folder: /repository/<version>/HostComponents/<esxi_version>.
Once the bundle has been stored locally, it can be installed with the following command: esxcli software vib install -d /<absolute_path>/nsx-lcp-<version>.zip
NOTE
At the present time, the VIBs installation from the offline bundle takes about five minutes and offers no intermediate feedback.
For this reason, open a second host session and run tail -f /var/log/esxupdate.log to monitor the whole process.
Once the NSX kernel modules and agents are installed, configuring the ESXi host as an NSX Data Plane Transport Node becomes straightforward:
- Firstly, retrieve the thumbprint of the NSX Manager node to join. From an NSX Manager appliance console run the
get certificate api thumbprintcommand. This command returns the unique certificate thumbprint used to securely identify the NSX Manager node. - Log in to the ESXi host shell and invoke the NSXCLI with the
nsxclicommand. - Next, join the host to the NSX Management Plane manually. Run the following NSXCLI command, replacing the placeholders with actual values:
join management-plane <Management_Node_IP> username <Admin_User> password <Admin_PWD> thumbprint <Management_Node_Thumbprint>. Ensure that IP and thumbprint both refer to the same NSX Manager node. Thumbprints are node-specific because each NSX Manager has a unique API certificate. Additionally, do not use the Management Cluster VIP for the join process. - Last, use the NSX Manager UI to configure the Host Switch providing the parameters described earlier in this post.
Edge Transport Nodes
Automated deployment through the NSX Manager UI
NSX Edge Transport Node virtual appliances can be deployed from the NSX Manager UI using a wizard. By navigating to System > Configuration > Fabric > Nodes > Edge Transport Nodes, locate and click the ADD EDGE NODE button.

- Enter a Name for the NSX Edge appliance in the vCenter Server inventory.
- Provide the Host Name/FQDN of the appliance.
- Add a Description.
- Select the Edge appliance Form Factor.
- The Advanced Resource Reservations section can be used to adjust CPU and memory reservations, as well as CPU shares.
- Optionally, choose different usernames for the “admin” and “audit” accounts.
- Set system root, and UI/API/CLI “admin” and “audit” accounts passwords.
- Select Compute Manager, Cluster, Resource Pool, Host, and Datastore for the appliance being deployed.
- Pick Management IP address Type and Assignment, as well as the Management Interface. Additionally, provide Search Domain Names, DNS, and NTP servers.
- Optionally, select Enable UPT mode for datapath interface. Universal Pass Through (UPT) enables the NSX Edge Node to leverage the Data Processing Units (DPU) / SmartNIC offload (see Part 5).
- Lastly, configure one or more Host Switch providing the parameters described earlier in this post.
When deployment begins, the NSX Manager Cluster hands over all collected parameters to the paired Compute Manager. It also provides the Edge appliance OVF template, which is locally stored in the /repository/<current_version>/Edge/ovf/ folder.
To conclude, the vCenter Server – acting as a Compute Manager – deploys the Edge virtual appliance. It then powers on the appliance and performs the initial configuration. Once the Edge node joins the Management Plane, NSX finalizes the Transport Node configuration automatically.
Manual deployment using the vSphere Client, OVF Tool, or PowerCLI, followed by NSXCLI and configuration in NSX Manager
Alternatively, an Edge Transport Node virtual appliance can be deployed through:
- The vSphere Client Deploy OVF Template wizard.
- The OVF Tool or the PowerCLI command line utilities.
In essence, the methods above require administrators to follow a familiar process, similar to the NSX Manager appliance deployment. With minimal adjustments, those procedures apply to NSX Edge Transport Node virtual appliances as well. Additionally, an option exists to automatically join the Management Plane during the appliance’s first boot.
In large enterprises with split roles, if the infrastructure team deploys the appliance, but lucks NSX Manager access, automated join isn’t viable. If the feature cannot be used, then an extra step becomes necessary:
- Firstly, retrieve the thumbprint of the NSX Manager node to join. From an NSX Manager appliance console run the
get certificate api thumbprintcommand. This command returns the unique certificate thumbprint used to securely identify the NSX Manager node. - Log in to the Edge appliance console and join the node to the NSX Management Plane manually. Run the following NSXCLI command, replacing the placeholders with actual values:
join management-plane <Management_Node_IP> username <Admin_User> password <Admin_PWD> thumbprint <Management_Node_Thumbprint>. Ensure that IP and thumbprint both refer to the same NSX Manager node. Thumbprints are node-specific because each NSX Manager has a unique API certificate. Additionally, do not use the Management Cluster VIP for the join process. - Last, navigate the NSX Manager UI to System > Configuration > Fabric > Nodes > Edge Transport Nodes. Configure the Edge Node Host Switch(es) providing the parameters described earlier in this post.
Manual deployment using the NSX Edge ISO image, followed by NSXCLI and configuration in NSX Manager.
A Bare-Metal Edge Transport Node supports the deployment through:
- An interactive installation from a bootable ISO image.
- An automated installation from a bootable ISO image.
- A scripted PXE Boot-based installation from an ISO image.
Once the Bare-Metal Edge Transport Node is up and running:
- Firstly, retrieve the thumbprint of the NSX Manager node to join. From an NSX Manager appliance console run the
get certificate api thumbprintcommand. This command returns the unique certificate thumbprint used to securely identify the NSX Manager node. - Log in to the Edge appliance console and join the node to the NSX Management Plane manually. Run the following NSXCLI command, replacing the placeholders with actual values:
join management-plane <Management_Node_IP> username <Admin_User> password <Admin_PWD> thumbprint <Management_Node_Thumbprint>. Ensure that IP and thumbprint both refer to the same NSX Manager node. Thumbprints are node-specific because each NSX Manager has a unique API certificate. Additionally, do not use the Management Cluster VIP for the join process. - Last, navigate the NSX Manager UI to System > Configuration > Fabric > Nodes > Edge Transport Nodes. Configure the Edge Node Host Switch(es) providing the parameters described earlier in this post.
Bare-Metal Transport Nodes
Automated deployment through the NSX Manager UI
Linux and Windows Bare Metal hosts can be prepared by clicking the ADD HOST NODE button in System > Configuration > Fabric > Nodes > Standalone. A wizard collects all the required parameters to connect to the bare-metal host, install NSX components, and configure the host as a Transport Node.
Manual deployment via the operating system’s package manager, followed by NSXCLI and configuration in NSX Manager.
To prepare a Linux or Windows server as a Bare-Metal Transport Node, it is also possible running an Ansible script. This option requires:
- Install Ansible following the instructions that can be reviewed at https://docs.ansible.com/ansible/latest/installation_guide/intro_installation.html
- Download and run the physical server Ansible Playbooks for NSX from https://github.com/vmware/bare-metal-server-integration-with-nsxt.
Despite being a viable option, VMware recommends using the NSX Manager UI to prepare physical servers for NSX networking.
Deployment validation
At the end of the Transport Node configuration or deployment process, we shall validate the successful implementation of the NSX Data Plane. Navigate to System > Configuration > Fabric > Hosts > Other Nodes to validate Host Transport Nodes or Standalone for Bare-Metal Transport Nodes. Alternatively, navigate to System > Configuration > Fabric > Edge Transport Nodes for the Edges.
Validate the nodes by checking Configuration State and Node Status columns of every Transport Node in the NSX UI. Additionally, the Management IP Address column show the IP address configured on the Transport Node to enable communication with the Management Cluster. Whereas TEP IP Addresses column lists the address(es) assigned to the kernel logical interface(s) for the GENEVE traffic.

The Configuration State column displays Success when the LCP Bundle installs and configures correctly. However, if an error occurs, the column shows an Install Failed message. Click the error link to open a popup window, view logs or launch a RESOLVE workflow to fix the problem automatically.
NOTE
When a vSphere Cluster shows Install Failed, first resolve issues at the cluster level. Then, attempt to remediate each host individually. If you skip cluster-level errors and target host-level issues directly, the UI blocks host-level remediation actions. Hence, always address cluster problems before working on host-specific failures.
Once installation succeeds, the Transport Node connects to the NSX Management Cluster and peers. Click the blue (i) icon beside Node Status to view connectivity details:
- Manager Connectivity: nsx-proxy agent to Management Plane, via TCP/1234 using NSX RPC.
- Controller Connectivity: nsx-proxy agent to Central Control Plane, via TCP/1235 using NSX RPC.
- PNIC/Bond Status: Shows uplink interfaces status for the Transport Node.
- Tunnel Status: Indicates GENEVE tunnel health via UDP/6081 to other Transport Nodes.
CLI-based validation
NSX Data Plane Transport Nodes deployment can also be validated using the CLI and executing the following commands:
- ESXi Hypervisor Transport Nodes:
esxcli software vib list | grep -E "Name|nsx|vsip*"to list the installed VIB packages on the host.esxcli system module list | grep -E "Name|nsx"to list the VMkernel modules that the system knows about.vmkload_mod -l | grep -E "Name|nsx"to list the VMkernel modules that are currently loaded./etc/init.d/nsx-proxy statusto check the status of the nsx-proxy agent.esxcli network ip connection list | grep -E "Name|1234|1235"to check the nsx-proxy connections to Management and Control Plane.
- Edge Transport Nodes:
/etc/init.d/nsx-proxy statusto check the status of the nsx-proxy agent.ss -p | grep -E "Port|1234|1235"to check the nsx-proxy connections to Management and Control Plane.
- Bare Metal Transport Nodes:
yum list installed | grep nsxORrpm -qa | grep nsxto list the installed packages on RedHat Enterprise Linux, CentOS, or Oracle Linux.dpkg --get-selections | grep nsxto list the installed packages on Ubuntu.rpm -qa | grep nsxto list the installed packages on SUSE Linux Enterprise Server.tasklist /V | grep nsx findstr "nsx ovs"from the Windows command line./etc/init.d/nsx-proxy statusto check the status of the nsx-proxy agent.ss -p | grep -E "Port|1234|1235"on Linux to check the nsx-proxy connections to Management and Control Plane.netstat -b | findstr 1234 1235on Windows to check the nsx-proxy connections to Management and Control Plane.
Continue to Part 5…
In Part 4 of the Exploring NSX Building Blocks module, we have covered the core components of the NSX Data Plane. We discussed prerequisites, deployment and validation, as well as using either the NSX Manager UI and the CLI tools. Continue to the fifth part of this module where we explore Data Processing Units (DPUs) and SmartNICs which offer hardware offloading capabilities. As a result, DPUs help reduce CPU load, accelerate network processing, and enhance isolation, making them ideal for production-grade enterprise environments.
